mirror of
https://github.com/zeek/zeek.git
synced 2025-10-02 06:38:20 +00:00
Merge remote-tracking branch 'micrictor/master'
* micrictor/master: Add a field to Modbus/TCP log to indicate the Modbus PDU type Add modbus transaction and unit ids to logs Enable modbus logging for requests
This commit is contained in:
commit
7fe6290974
6 changed files with 40028 additions and 20000 deletions
|
@ -16,8 +16,14 @@ export {
|
|||
uid: string &log;
|
||||
## Identifier for the connection.
|
||||
id: conn_id &log;
|
||||
## Modbus transaction ID
|
||||
tid: count &log &optional;
|
||||
## The terminal unit identifier for the message
|
||||
unit: count &log &optional;
|
||||
## The name of the function message that was sent.
|
||||
func: string &log &optional;
|
||||
## Whether this PDU was a response ("RESP") or request ("REQ")
|
||||
pdu_type: string &log &optional;
|
||||
## The exception if the response was a failure.
|
||||
exception: string &log &optional;
|
||||
};
|
||||
|
@ -48,14 +54,18 @@ event modbus_message(c: connection, headers: ModbusHeaders, is_orig: bool) &prio
|
|||
}
|
||||
|
||||
c$modbus$ts = network_time();
|
||||
c$modbus$tid = headers$tid;
|
||||
c$modbus$unit = headers$uid;
|
||||
c$modbus$func = function_codes[headers$function_code];
|
||||
## If this message is from the TCP originator, it is a request. Otherwise,
|
||||
## it is a response.
|
||||
c$modbus$pdu_type = is_orig ? "REQ" : "RESP";
|
||||
}
|
||||
|
||||
event modbus_message(c: connection, headers: ModbusHeaders, is_orig: bool) &priority=-5
|
||||
{
|
||||
# Only log upon replies.
|
||||
# Also, don't log now if this is an exception (log in the exception event handler)
|
||||
if ( ! is_orig && ( headers$function_code <= 0x81 || headers$function_code >= 0x98 ) )
|
||||
# Don't log now if this is an exception (log in the exception event handler)
|
||||
if ( headers$function_code <= 0x81 || headers$function_code >= 0x98 )
|
||||
Log::write(LOG, c$modbus);
|
||||
}
|
||||
|
||||
|
|