Broker had changed the semantics of remote logging: it sent over the
original Bro record containing the values to be logged, which on the
receiving side would then pass through the logging framework normally,
including triggering filters and events. The old communication system
however special-cases logs: it sends already processed log entries,
just as they go into the log files, and without any receiver-side
filtering etc. This more efficient as it short-cuts the processing
path, and also avoids the more expensive Val serialization. It also
lets the sender determine the specifics of what gets logged (and how).
This commit changes Broker over to now use the same semantics as the
old communication system.
TODOs:
- The new Broker code doesn't have consistent #ifdefs yet.
- Right now, when a new log receiver connects, all existing logs
are broadcasted out again to all current clients. That doesn't so
any harm, but is unncessary. Need to add a way to send the
existing logs to just the new client.
When receiving a remote log via broker, there was a bug that would
prevent a log from being written if the log record contained a field
without the &log attribute that was followed by a field with the &log
attribute.
Updated a test case to catch this error.