Commit graph

8 commits

Author SHA1 Message Date
Jon Siwek
c911d03c30 Adjust modbus register array parsing.
For modbus message types that include variable amount of register values
(uint16[]), setting a &length attribute without an explicit array size
could trigger a parsing assertion since it allows for the "element" data
pointer to travel past the "end of data" (e.g. when &length is odd).
This is changed to now give both an array size and &length to earlier
terminate the parsing of elements before the assert is checked and
so a single out-of-bound check can be done for the entire array
(leaving off &length causes an out-of-bound check for each element).

Added another parameter to modbus events that carry register arrays to
the script-layer which indicates the associated byte count from the
message (allowing for invalid values to be detected):

    modbus_read_holding_registers_response
    modbus_read_input_registers_response
    modbus_write_multiple_registers_request
    modbus_read_write_multiple_registers_request
    modbus_read_write_multiple_registers_response
    modbus_read_fifo_queue_response
2012-11-12 16:40:16 -06:00
Seth Hall
a2f336cc72 Final touches to modbus analyzer for now.
- There are still some broken events in the modbus analyzer because
  I don't have traffic to test with (coil and record related events primarily).

- There are a few example scripts in policy/protocols/modbus
2012-10-31 23:34:43 -04:00
Seth Hall
009efbcb27 Major revisions to Modbus analyzer support (not quite done yet).
- Renamed many data structures to align with most recent standard.

- Reworked modbus events to make them more canonically "Bro".

- Converted the Modbus analyzer to a simpler style for easier maintenance.

- Modbus coil related events still don't work (I haven't finished the
  function for converting the data structures).

- Modbus file record events remain incomplete.
2012-09-17 09:19:52 -04:00
Robin Sommer
cbb31cedc3 Merge remote-tracking branch 'origin/topic/dina/modbus' into topic/robin/modbus-merge
* origin/topic/dina/modbus:
  put some make-up on Modbus analyser
  Modbus analyser, added support: FC=20,21
  Modbus analyzer,added support: FC=1,2,15,24
  Modbus analyzer, current support: FC=3,4,5,6,7,16,22,23

I cleaned up the code a bit, mainly layout style.

I did not include the *.bro scripts for now, but a test script
../testing/btest/scripts/base/protocols/modbus/events.bro that prints
out the value for each event.

Merged the Modbus traces from the ics repository into a single trace
as input for the test. They currently trigger 20 of the 34 events.

Addresses #870.
2012-08-29 17:58:41 -07:00
dina
fb0d93de1e put some make-up on Modbus analyser 2012-08-24 10:21:04 +02:00
dina
c58c6791c5 Modbus analyser, added support: FC=20,21 2012-08-22 16:47:34 +02:00
dina
e8f4c7bc3d Modbus analyzer,added support: FC=1,2,15,24 2012-08-21 15:39:52 +02:00
dina
5c756dcebf Modbus analyzer, current support: FC=3,4,5,6,7,16,22,23 2012-08-20 13:30:22 +02:00