Emmanuele Zambon
792aacc8e5 Fix issues with Modbus message logging
This commit fixes three issues with Zeek's Modbus message logging:

1 - Some exception responses (e.g., READ_COILS_EXCEPTION) are logged
    twice: once without and once with the exception message.
2 - Some exception responses (e.g., PROGRAM_484_EXCEPTION) are not
    logged.
3 - Some known but reserved function codes (e.g., PROGRAM_UNITY) are
    logged as unk-xxx (e.g., unk-90), while it would be possible to
    log their known name.

To address these inconsistencies, the modbus parser has been updated
to parse all exception responses (i.e., all responses where the MSB
of the function code is set) using the already defined Exception
message.
Also, the Modbus main.zeek script has been updated to consistently
demand logging exception responses to the specialized
modbus_exception event, rather than logging some exception responses
in the modbus_message event and others in the modbus_exception event.
Finally, the main.zeek script has been updated to make sure that
for every known function code, the corresponding exception code was
also present, and the enumeration of known function codes in
consts.zeek has been expanded.

Closes #3984
2024-10-30 13:12:27 +01:00
Tim Wojtulewicz
406a406813 Modbus: Add support for Encapsulation Interface Transport (FC=2B) requests and responses 2023-08-07 13:44:37 -07:00
Tim Wojtulewicz
f14be0de29 Modbus: Add support for Diagnostics (FC=8) requests and responses 2023-08-07 13:44:37 -07:00
Michael Torres
b85801aa7e Add a field to Modbus/TCP log to indicate the Modbus PDU type
Add the `pdu_type` field to Modbus over TCP logs to indicate whether the Modbus
message was a request or a response. Due to the client/server nature of Modbus
over TCP/IP, all messages from the TCP session originator are requests, while
all messages from the TCP session responder are responses.

Adding this information to the default log surfaces protocol metadata in a way
that doesn't require users to understand the Modbus over TCP protocol.
2022-07-24 02:41:26 +00:00
Michael Torres
bab2036aa4 Add modbus transaction and unit ids to logs
Add transaction IDs and unit IDs to default modbus over TCP/IP logs.
Update the relevant testing baselines to account for the extra fields.
2022-07-17 21:02:37 +00:00
Christian Kreibich
0b674eb851 Baseline refresh to reflect btest 0.64 2020-12-06 20:19:49 -08:00
Johanna Amann
cdb6a1b6e6 Baseline updates after hash function change. 2016-07-13 10:11:37 -07:00
Jon Siwek
22bf3e1196 Increase UIDs to 96 bits w/ C/F prefix - BIT-1016
- The bit-length is adjustable via redef'ing bits_per_uid.

- Prefix 'C' is used for connection UIDS (including IP tunnels) and
  'F' for files.
2013-08-26 15:36:31 -05:00
Robin Sommer