fd5eb23fa6 Remove byte count parameter from modbus events carrying register arrays
Instead of these events being generated for invalid byte count values
(they should always be even, not odd), a protocol_violation is raised.

    modbus_read_holding_registers_response
    modbus_read_input_registers_response
    modbus_write_multiple_registers_request
    modbus_read_write_multiple_registers_request
    modbus_read_write_multiple_registers_response
    modbus_read_fifo_queue_respons
2012-11-13 12:09:14 -06:00
Jon Siwek
c911d03c30 Adjust modbus register array parsing.
For modbus message types that include variable amount of register values
(uint16[]), setting a &length attribute without an explicit array size
could trigger a parsing assertion since it allows for the "element" data
pointer to travel past the "end of data" (e.g. when &length is odd).
This is changed to now give both an array size and &length to earlier
terminate the parsing of elements before the assert is checked and
so a single out-of-bound check can be done for the entire array
(leaving off &length causes an out-of-bound check for each element).

Added another parameter to modbus events that carry register arrays to
the script-layer which indicates the associated byte count from the
message (allowing for invalid values to be detected):

    modbus_read_holding_registers_response
    modbus_read_input_registers_response
    modbus_write_multiple_registers_request
    modbus_read_write_multiple_registers_request
    modbus_read_write_multiple_registers_response
    modbus_read_fifo_queue_response
2012-11-12 16:40:16 -06:00
Robin Sommer
4e12813445 Fixing tests after modbus merge. 2012-11-05 15:58:38 -08:00
Robin Sommer
86ce564107 Merge remote-tracking branch 'remotes/origin/topic/seth/modbus-merge'
* remotes/origin/topic/seth/modbus-merge:
  Small modbus documentation update and tiny refactoring.
  Final touches to modbus analyzer for now.
  Major revisions to Modbus analyzer support (not quite done yet).
  put some make-up on Modbus analyser
  Modbus analyser, added support: FC=20,21
  Modbus analyzer,added support: FC=1,2,15,24
  Modbus analyzer, current support: FC=3,4,5,6,7,16,22,23

Closes #915.
2012-11-05 15:26:57 -08:00
Seth Hall
c32b179ac5 Small modbus documentation update and tiny refactoring. 2012-10-31 23:57:38 -04:00
Seth Hall
a2f336cc72 Final touches to modbus analyzer for now.
- There are still some broken events in the modbus analyzer because
  I don't have traffic to test with (coil and record related events primarily).

- There are a few example scripts in policy/protocols/modbus
2012-10-31 23:34:43 -04:00