.. _cluster-pf-ring:
|
|
|
|
===================
|
|
PF_RING Setup Guide
|
|
===================
|
|
|
|
Installing PF_RING
|
|
******************
|
|
|
|
1. Download and install PF_RING for your system following the instructions
|
|
`here <http://www.ntop.org/get-started/download/#PF_RING>`_. The following
|
|
commands will install the PF_RING libraries and kernel module (replace
|
|
the version number 5.6.2 in this example with the version that you
|
|
downloaded)::
|
|
|
|
cd /usr/src
|
|
tar xvzf PF_RING-5.6.2.tar.gz
|
|
cd PF_RING-5.6.2/userland/lib
|
|
./configure --prefix=/opt/pfring
|
|
make install
|
|
|
|
cd ../libpcap
|
|
./configure --prefix=/opt/pfring
|
|
make install
|
|
|
|
cd ../tcpdump-4.1.1
|
|
./configure --prefix=/opt/pfring
|
|
make install
|
|
|
|
cd ../../kernel
|
|
make
|
|
make install
|
|
|
|
modprobe pf_ring enable_tx_capture=0 min_num_slots=32768
|
|
|
|
Refer to the documentation for your Linux distribution on how to load the
|
|
pf_ring module at boot time. You will need to install the PF_RING
|
|
library files and kernel module on all of the workers in your cluster.
|
|
|
|
2. Download the Zeek source code.
|
|
|
|
3. Configure and install Zeek using the following commands::
|
|
|
|
./configure --with-pcap=/opt/pfring
|
|
make
|
|
make install
|
|
|
|
4. Make sure Zeek is correctly linked to the PF_RING libpcap libraries::
|
|
|
|
ldd /usr/local/zeek/bin/zeek | grep pcap
|
|
libpcap.so.1 => /opt/pfring/lib/libpcap.so.1 (0x00007fa6d7d24000)
|
|
|
|
5. Configure ZeekControl to use PF_RING (explained below).
|
|
|
|
6. Run "zeekctl install" on the manager. This command will install Zeek and
|
|
required scripts to all machines in your cluster.
|
|
|
|
Using PF_RING
|
|
*************
|
|
|
|
In order to use PF_RING, you need to specify the correct configuration
|
|
options for your worker nodes in ZeekControl's node configuration file.
|
|
Edit the ``node.cfg`` file and specify ``lb_method=pf_ring`` for each of
|
|
your worker nodes. Next, use the ``lb_procs`` node option to specify how
|
|
many Zeek processes you'd like that worker node to run, and optionally pin
|
|
those processes to certain CPU cores with the ``pin_cpus`` option (CPU
|
|
numbering starts at zero). The correct ``pin_cpus`` setting to use is
|
|
dependent on your CPU architecture (Intel and AMD systems enumerate
|
|
processors in different ways). Using the wrong ``pin_cpus`` setting
|
|
can cause poor performance. Here is what a worker node entry should
|
|
look like when using PF_RING and CPU pinning::
|
|
|
|
[worker-1]
|
|
type=worker
|
|
host=10.0.0.50
|
|
interface=eth0
|
|
lb_method=pf_ring
|
|
lb_procs=10
|
|
pin_cpus=2,3,4,5,6,7,8,9,10,11
|
|
|
|
|
|
Using PF_RING+DNA with symmetric RSS
|
|
************************************
|
|
|
|
You must have a PF_RING+DNA license in order to do this. You can sniff
|
|
each packet only once.
|
|
|
|
1. Load the DNA NIC driver (i.e. ixgbe) on each worker host.
|
|
|
|
2. Run "ethtool -L dna0 combined 10" (this will establish 10 RSS queues
|
|
on your NIC) on each worker host. You must make sure that you set the
|
|
number of RSS queues to the same as the number you specify for the
|
|
lb_procs option in the node.cfg file.
|
|
|
|
3. On the manager, configure your worker(s) in node.cfg::
|
|
|
|
[worker-1]
|
|
type=worker
|
|
host=10.0.0.50
|
|
interface=dna0
|
|
lb_method=pf_ring
|
|
lb_procs=10
|
|
|
|
|
|
Using PF_RING+DNA with pfdnacluster_master
|
|
******************************************
|
|
|
|
You must have a PF_RING+DNA license and a libzero license in order to do
|
|
this. You can load balance between multiple applications and sniff the
|
|
same packets multiple times with different tools.
|
|
|
|
1. Load the DNA NIC driver (i.e. ixgbe) on each worker host.
|
|
|
|
2. Run "ethtool -L dna0 1" (this will establish 1 RSS queues on your NIC)
|
|
on each worker host.
|
|
|
|
3. Run the pfdnacluster_master command on each worker host. For example::
|
|
|
|
pfdnacluster_master -c 21 -i dna0 -n 10
|
|
|
|
Make sure that your cluster ID (21 in this example) matches the interface
|
|
name you specify in the node.cfg file. Also make sure that the number
|
|
of processes you're balancing across (10 in this example) matches
|
|
the lb_procs option in the node.cfg file.
|
|
|
|
4. If you are load balancing to other processes, you can use the
|
|
pfringfirstappinstance variable in zeekctl.cfg to set the first
|
|
application instance that Zeek should use. For example, if you are running
|
|
pfdnacluster_master with "-n 10,4" you would set
|
|
pfringfirstappinstance=4. Unfortunately that's still a global setting
|
|
in zeekctl.cfg at the moment but we may change that to something you can
|
|
set in node.cfg eventually.
|
|
|
|
5. On the manager, configure your worker(s) in node.cfg::
|
|
|
|
[worker-1]
|
|
type=worker
|
|
host=10.0.0.50
|
|
interface=dnacluster:21
|
|
lb_method=pf_ring
|
|
lb_procs=10
|