:tocdepth: 3
base/protocols/modbus/main.zeek
===============================
.. zeek:namespace:: Modbus
Base Modbus analysis script.
:Namespace: Modbus
:Imports: :doc:`base/protocols/modbus/consts.zeek </scripts/base/protocols/modbus/consts.zeek>`
Summary
~~~~~~~
Types
#####
============================================== =
:zeek:type:`Modbus::Info`: :zeek:type:`record`
============================================== =
Redefinitions
#############
==================================================================== ==========================================================
:zeek:type:`Log::ID`: :zeek:type:`enum`
* :zeek:enum:`Modbus::LOG`
:zeek:type:`connection`: :zeek:type:`record`
:New Fields: :zeek:type:`connection`
modbus: :zeek:type:`Modbus::Info` :zeek:attr:`&optional`
:zeek:id:`likely_server_ports`: :zeek:type:`set` :zeek:attr:`&redef`
==================================================================== ==========================================================
Events
######
================================================= ===================================================================
:zeek:id:`Modbus::log_modbus`: :zeek:type:`event` Event that can be handled to access the Modbus record as it is sent
on to the logging framework.
================================================= ===================================================================
Hooks
#####
=========================================================== =
:zeek:id:`Modbus::log_policy`: :zeek:type:`Log::PolicyHook`
=========================================================== =
Detailed Interface
~~~~~~~~~~~~~~~~~~
Types
#####
.. zeek:type:: Modbus::Info
:source-code: base/protocols/modbus/main.zeek 12 29
:Type: :zeek:type:`record`
.. zeek:field:: ts :zeek:type:`time` :zeek:attr:`&log`
Time of the request.
.. zeek:field:: uid :zeek:type:`string` :zeek:attr:`&log`
Unique identifier for the connection.
.. zeek:field:: id :zeek:type:`conn_id` :zeek:attr:`&log`
Identifier for the connection.
.. zeek:field:: tid :zeek:type:`count` :zeek:attr:`&log` :zeek:attr:`&optional`
Modbus transaction ID
.. zeek:field:: unit :zeek:type:`count` :zeek:attr:`&log` :zeek:attr:`&optional`
The terminal unit identifier for the message
.. zeek:field:: func :zeek:type:`string` :zeek:attr:`&log` :zeek:attr:`&optional`
The name of the function message that was sent.
.. zeek:field:: pdu_type :zeek:type:`string` :zeek:attr:`&log` :zeek:attr:`&optional`
Whether this PDU was a response ("RESP") or request ("REQ")
.. zeek:field:: exception :zeek:type:`string` :zeek:attr:`&log` :zeek:attr:`&optional`
The exception if the response was a failure.
.. zeek:field:: track_address :zeek:type:`count` :zeek:attr:`&default` = ``0`` :zeek:attr:`&optional`
(present if :doc:`/scripts/policy/protocols/modbus/track-memmap.zeek` is loaded)
Events
######
.. zeek:id:: Modbus::log_modbus
:source-code: base/protocols/modbus/main.zeek 33 33
:Type: :zeek:type:`event` (rec: :zeek:type:`Modbus::Info`)
Event that can be handled to access the Modbus record as it is sent
on to the logging framework.
Hooks
#####
.. zeek:id:: Modbus::log_policy
:source-code: base/protocols/modbus/main.zeek 10 10
:Type: :zeek:type:`Log::PolicyHook`