zeek/scripts/base/packet-protocols/vlan/main.zeek
2023-02-10 15:30:01 -07:00

13 lines
965 B
Text

module PacketAnalyzer::VLAN;
event zeek_init() &priority=20
{
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x8847, PacketAnalyzer::ANALYZER_MPLS);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x88E7, PacketAnalyzer::ANALYZER_PBB);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x0800, PacketAnalyzer::ANALYZER_IP);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x86DD, PacketAnalyzer::ANALYZER_IP);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x0806, PacketAnalyzer::ANALYZER_ARP);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x8035, PacketAnalyzer::ANALYZER_ARP);
PacketAnalyzer::register_packet_analyzer(PacketAnalyzer::ANALYZER_VLAN, 0x8100, PacketAnalyzer::ANALYZER_VLAN);