For modbus message types that include variable amount of register values (uint16[]), setting a &length attribute without an explicit array size could trigger a parsing assertion since it allows for the "element" data pointer to travel past the "end of data" (e.g. when &length is odd). This is changed to now give both an array size and &length to earlier terminate the parsing of elements before the assert is checked and so a single out-of-bound check can be done for the entire array (leaving off &length causes an out-of-bound check for each element). Added another parameter to modbus events that carry register arrays to the script-layer which indicates the associated byte count from the message (allowing for invalid values to be detected): modbus_read_holding_registers_response modbus_read_input_registers_response modbus_write_multiple_registers_request modbus_read_write_multiple_registers_request modbus_read_write_multiple_registers_response modbus_read_fifo_queue_response
5 lines
2.1 KiB
Text
5 lines
2.1 KiB
Text
modbus_read_input_registers_request, [orig_h=10.1.1.234, orig_p=51411/tcp, resp_h=10.10.5.104, resp_p=502/tcp], [tid=1119, pid=0, uid=255, function_code=4], 900, 147
|
|
modbus_read_input_registers_response, [orig_h=10.1.1.234, orig_p=51411/tcp, resp_h=10.10.5.104, resp_p=502/tcp], [tid=2606, pid=0, uid=255, function_code=4], [0, 0, 0, 0, 0, 0, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690], 100, 200
|
|
modbus_read_input_registers_response, [orig_h=10.1.1.234, orig_p=51411/tcp, resp_h=10.10.5.104, resp_p=502/tcp], [tid=6714, pid=0, uid=255, function_code=4], [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 3840, 0, 0, 31, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 37, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 64, 129
|
|
modbus_read_input_registers_request, [orig_h=10.1.1.234, orig_p=51411/tcp, resp_h=10.10.5.104, resp_p=502/tcp], [tid=12993, pid=0, uid=255, function_code=4], 400, 100
|
|
modbus_read_input_registers_response, [orig_h=10.1.1.234, orig_p=51411/tcp, resp_h=10.10.5.104, resp_p=502/tcp], [tid=17667, pid=0, uid=255, function_code=4], [49, 18012, 51, 42, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 49, 50, 51, 54324, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 69, 63, 64, 65, 66, 67, 68, 49, 189, 51, 52, 53, 54, 4151, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 136, 49, 50, 51, 212, 53, 54, 170, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690, 43690], 100, 200
|